Menu

IYRO MP Series

Mono PERC Solar Modules

250 – 585 Wp Half-cut · MBB IP68 junction box

High-efficiency mono-facial half-cut modules with multi-busbar cells, IP68 junction box and positive power tolerance.

  • Up to 21.08% module efficiency
  • Positive power tolerance up to +4.99 Wp
  • 5400 Pa snow load, 2400 Pa wind load
  • Excellent anti-PID performance guarantee
  • 10-year product · 25-year linear performance warranty
Mono PERC Solar Modules

Available Models

21 ratings in one series

Same construction and warranty across the range. Pick a rating to see its full specification.

Model

IYRO MP Series 540 W

Selected — IYRO MP Series 540 W

Peak power (Pmax)
540 Wp
Module efficiency
21.08 %
Open-circuit voltage
49.23 V
Short-circuit current
13.71 A
Voltage at Pmax
42.42 V
Current at Pmax
12.80 A
Cell count
144 (12 × 6 | 12)
Dimensions
2278 × 1134 × 40 mm
Weight
28.3 kg

The Short Version

The workhorse, and still the right answer on most roofs.

A mature, widely understood and inexpensive module built on half-cut mono cells. Where budget rather than roof area is the constraint — which is most projects — it remains the sensible specification, and the series runs from 250 W right up to 585 W.

Positive power tolerance

Sorted to 0 to +4.99 Wp, so a module never ships under its nameplate rating.

Multi-busbar cells

Better light trapping and current collection, and lower resistive loss than a full-cell layout.

Anti-PID performance guarantee

Specified for humid and coastal sites where potential-induced degradation bites hardest.

Reduced hot-spot loss

Individual bypass diodes in an IP68 split junction box.

High mechanical load rating

5400 Pa snow and 2400 Pa wind.

Strong low-light response

Useful output earlier and later in the day, and through overcast conditions.

Applications

Where this range is specified

Residential rooftop

Residential rooftop

250–360 W for compact and shaded roofs.

Commercial rooftop

Commercial rooftop

500–585 W where area is not the constraint.

Industrial captive

Industrial captive

Cost-led builds with generous roof area.

Institutional

Institutional

Budget-scrutinised public and campus projects.

Compare

The full series, side by side

Selected model highlighted.

IYRO MP Series — full specification.
Model 585 W 550 W 545 W 540 W 535 W 500 W 460 W 450 W 440 W 430 W 400 W 360 W 355 W 350 W 340 W 335 W 270 W 265 W 260 W 255 W 250 W
Peak power (Pmax) (Wp) 585 550 545 540 535 500 460 450 440 430 400 360 355 350 340 335 270 265 260 255 250
Module efficiency (%) 20.93 21.08 21.08 21.08 20.89 21.05 19.46 20.78 20.13 19.85 20.44 20.59 20.30 20.02 19.44 19.16 20.38 20.01 19.63 19.25 18.87
Open-circuit voltage (V) 53.78 49.70 49.47 49.23 49.03 45.48 43.88 41.36 40.95 40.55 37.01 32.78 32.58 32.38 32.18 31.98 24.80 24.60 24.40 24.20 24.00
Short-circuit current (A) 13.83 13.83 13.77 13.71 13.65 13.83 13.35 13.83 13.71 13.59 13.77 13.71 13.65 13.59 13.83 13.79 13.76 13.65 13.59
Voltage at Pmax (V) 45.29 42.64 42.19 42.42 41.97 38.76 36.92 34.89 34.41 33.92 31.13 28.04 27.78 27.50 26.84 26.57 20.95 20.66 20.35 20.05 19.75
Current at Pmax (A) 12.92 12.90 12.85 12.80 12.75 12.90 12.46 12.90 12.79 12.68 12.86 12.84 12.78 12.73 12.67 12.61 12.89 12.83 12.78 12.72 12.66
Cell count 156 144 (12 × 6 | 12) 144 (12 × 6 | 12) 144 (12 × 6 | 12) 144 (12 × 6 | 12) 132 120 120 120 120 108 96 96 96 96 96 72 (6 × 6 || 2) 72 (6 × 6 || 2) 72 (6 × 6 || 2) 72 (6 × 6 || 2) 72 (6 × 6 || 2)
Dimensions (mm) 2278 × 1134 × 40 2278 × 1134 × 40 2278 × 1134 × 40 2278 × 1134 × 40 1168 × 1134 × 40 1168 × 1134 × 40 1168 × 1134 × 40 1168 × 1134 × 40 1168 × 1134 × 40
Weight (kg) 28.3 28.3 28.3 28.3 15 15 15 15 15

Common To Every Model

Cell typeMonocrystalline, half-cut, multi-busbar
Maximum system voltage1500 V DC
Maximum series fuse rating25 A
Power tolerance0 to +4.99 Wp
Front glassLow-iron high-transmission AR-coated tempered glass
EncapsulantEVA
Back sheetPolyvinyl fluoride composite film
FrameAnodised aluminium, hollow profile
Junction boxIP68 split junction box with individual bypass diode
ConnectorMC4 compatible
Mechanical load5400 Pa snow, 2400 Pa wind
NOCT45 ± 2 °C
Temperature coefficient of Pmax−0.39 %/°C
Temperature coefficient of Voc−0.30 %/°C
Temperature coefficient of Isc+0.05 %/°C
Operating temperature−40 °C to +85 °C
Product warranty10 years
Performance warranty25 years linear

Questions

The ones we get on the phone.

Technical support
Should I choose this or TOPCon?

If roof area is the constraint, TOPCon — more kW in the same footprint, and a bifacial rear-side gain on top. If budget is the constraint and area is not, the mono-facial series. We will quote both against your layout.

What ratings are actually available?

Twenty-one, from 250 W to 585 W, on 72, 96, 108, 120, 132, 144 and 156 cell layouts. The smaller cell counts suit compact roofs; the 144-cell modules at 2278 × 1134 mm are the commercial workhorse.

What is the power tolerance?

Positive only — 0 to +4.99 Wp. A 540 W module will flash at 540 W or better, never below.

What is the warranty?

10 years product and 25 years linear performance.

Request Pricing

Tell us the rating and the volume.

Pricing, current lead time and the datasheet come back within one working day. Dealer, project and tender quantities all welcome.

Used only to prepare your quotation. Privacy policy