Menu

IYRO NT Series

N-Type TOPCon Solar Modules

560 – 600 Wp Framed dual glass · bifacial 144 half-cut · MBB

Framed dual-glass bifacial modules on N-type TOPCon cells — 144 half-cut cells, multi-busbar, rated for 5400 Pa snow and 2400 Pa wind.

  • Up to 23.26% module efficiency
  • Bifaciality factor 80 ± 5%
  • Rated backside gain to +25% power output
  • 5400 Pa snow load, 2400 Pa wind load
  • 10-year product · 25-year linear performance warranty
N-Type TOPCon Solar Modules

Available Models

9 ratings in one series

Same construction and warranty across the range. Pick a rating to see its full specification.

Model

IYRO NT Series 580 W

Selected — IYRO NT Series 580 W

Peak power (Pmax)
580 Wp
Module efficiency
22.48 %
Open-circuit voltage
51.30 V
Short-circuit current
14.28 A
Voltage at Pmax
43.13 V
Current at Pmax
13.45 A
Cell count
144 (91 × 182 mm)
Dimensions
2278 × 1134 × 35 mm
Weight
32.3 kg

The Short Version

A thin oxide layer, and less of your power lost as heat.

TOPCon puts an ultra-thin tunnel oxide between the silicon and the contact. Carriers still pass; recombination at the contact largely does not. More output from the same roof area, and noticeably less loss on a 45 °C afternoon than a PERC module of the same rating.

Higher module efficiency

Up to 23.26% at STC, so a fixed roof carries more kW and balance-of-system cost per watt falls.

Bifacial, 80 ± 5% bifaciality

Rear-side generation on top of the front-side rating — the brochure rates gain scenarios to +25%.

Best-in-class thermal coefficients

Less power lost per degree above 25 °C — visible every summer afternoon.

Better weak-light performance

Useful output earlier and later in the day, and through overcast conditions.

Enhanced crack tolerance

Half-cut multi-busbar layout, rated for 5400 Pa snow and 2400 Pa wind load.

Excellent PID resistance

PID-free, UV-resistant encapsulation for humid and coastal sites.

Applications

Where this range is specified

Residential rooftop

Residential rooftop

560–575 W for 3–10 kW domestic arrays.

Commercial rooftop

Commercial rooftop

580–600 W balances string length against roof access.

Ground mount

Ground mount

Bifacial rear gain gets its best return over reflective ground cover.

Utility scale

Utility scale

Dual-glass construction for long-duration outdoor exposure.

Compare

The full series, side by side

Selected model highlighted.

IYRO NT Series — full specification.
Model 560 W 565 W 570 W 575 W 580 W 585 W 590 W 595 W 600 W
Peak power (Pmax) (Wp) 560 565 570 575 580 585 590 595 600
Module efficiency (%) 21.71 21.90 22.09 22.29 22.48 22.67 22.87 23.06 23.26
Open-circuit voltage (V) 50.50 50.70 50.90 51.10 51.30 51.50 51.70 51.90 52.10
Short-circuit current (A) 13.93 14.02 14.10 14.20 14.28 14.36 14.45 14.53 14.61
Voltage at Pmax (V) 42.44 42.61 42.77 42.94 43.13 43.27 43.45 43.62 43.83
Current at Pmax (A) 13.20 13.26 13.33 13.40 13.45 13.52 13.58 13.65 13.69
Cell count 144 (91 × 182 mm) 144 (91 × 182 mm) 144 (91 × 182 mm) 144 (91 × 182 mm) 144 (91 × 182 mm) 144 (91 × 182 mm) 144 (91 × 182 mm) 144 (91 × 182 mm) 144 (91 × 182 mm)
Dimensions (mm) 2278 × 1134 × 35 2278 × 1134 × 35 2278 × 1134 × 35 2278 × 1134 × 35 2278 × 1134 × 35 2278 × 1134 × 35 2278 × 1134 × 35 2278 × 1134 × 35 2278 × 1134 × 35
Weight (kg) 32.3 32.3 32.3 32.3 32.3 32.3 32.3 32.3 32.3

Common To Every Model

Cell technologyTOPCon N-type mono bifacial, half-cut, multi-busbar
Cell size91 × 182 mm
Cell arrangement144 cells (12 × 6 || 12 × 6)
Bifaciality factor80 ± 5%
Backside power gainRated at 10%, 15%, 20% and 25% — dependent on plant design and location
Front / back glass2 mm low-iron semi-tempered glass
EncapsulantPID free and UV resistant
Back sheetDual glass (framed)
FrameAnodised aluminium alloy
Junction boxIP68, weatherproof PPO
Cable and connectorIP68 rated, MC4 compatible
Cable cross-section and length4 mm² × 500 mm
Mechanical load5400 Pa snow, 2400 Pa wind
NOCT43 ± 2 °C
Operating temperature−40 °C to +85 °C
Temperature coefficient of Isc (α)0.046 %/°C
Temperature coefficient — second row, unlabelled in datasheet−0.26 %/°C
Temperature coefficient — third row, unlabelled in datasheet−0.30 %/°C
Product warranty10 years
Performance warranty25 years linear
CertificationIS 14286:2010 / IEC 61215:2005, IS/IEC 61730 (Part 1 & 2):2004, IEC TS 62804-1:2015, IEC 61701:2020

Questions

The ones we get on the phone.

Technical support
What actually changes with TOPCon versus Mono PERC?

A tunnel-oxide layer cuts recombination at the rear contact. Higher efficiency ceiling and better temperature coefficients. On a fixed roof that means more kW installed; over 25 years, more kWh from the same kW.

Which rating should I specify for a rooftop?

The series runs 560 W to 600 W in 5 W steps on one physical size — 2278 × 1134 × 35 mm at 32.3 kg. Specify by string voltage and roof area rather than by rating alone; the module handling weight does not change across the range.

Are these modules bifacial?

The whole series is — framed dual glass, bifaciality factor 80 ± 5%. The datasheet rates backside gain at 10%, 15%, 20% and 25% scenarios, but states plainly that actual gain depends on plant design and location, so we quote it per site rather than as a headline number.

What is the warranty?

10 years product and 25 years linear performance, against IS 14286:2010 / IEC 61215:2005, IS/IEC 61730 Parts 1 and 2, IEC TS 62804-1:2015 and IEC 61701:2020.

Request Pricing

Tell us the rating and the volume.

Pricing, current lead time and the datasheet come back within one working day. Dealer, project and tender quantities all welcome.

Used only to prepare your quotation. Privacy policy

Also In Range